010-80330210 ★ 13810805582 ★ 13581938686【诚招代理】

Product Introduction

1、 Product Introduction:

The XH-GY01 integrated steel bar detector is mainly used to detect the construction quality of reinforced concrete, such as the position, thickness of protective layer, distribution and direction of steel bars, and diameter of steel bars in concrete structures such as housing engineering, bridges, tunnels, dams, and road surfaces; It can also detect and locate the direction distribution of magnetic materials in non magnetic materials; Quality control of construction and supervision, quality acceptance of reinforced concrete engineering, safety appraisal of buildings, road maintenance, reinforcement by planting steel bars, steel bar testing of water conservancy and civil air defense engineering, and testing of magnetic materials in various non-magnetic materials (such as wires and cables, magnetic pipelines).

2、 According to standards:

GB 50010-2010 "Code for Design of Concrete Structures" (2015 Edition) GB 50204-2015 "Code for Acceptance of Construction Quality of Concrete Structures" GB/T 50344-2019 "Technical Standards for Inspection of Building Structures" JGJ/T 152-2019 "Technical Regulations for Inspection of Steel Bars in Concrete" DB11/T 365-2016 "Technical Regulations for Inspection of Thickness and Diameter of Steel Reinforcement Cover" GB/T 50784-2013 "Technical Standards for Field Inspection of Concrete Structures" JJF 1224-2009 Calibration Specification for Thickness Measuring Instruments for Steel Reinforcement Cover and Floor Slabs

3、 Instrument features:

Advantages:

1. Six major detection functions

2. Accurate to 1 decimal place

3. The detection speed is 5 times that of a regular steel bar tester

4. High definition LCD delicate

5. Theme switching

6. Normative revisions

7. Data correction

8. Surface detection

9. Switching vibration

10. Nine types of testing reports

A dedicated JGJ regulation measurement mode is set up, with three parts of each steel bar tested twice, and the average value is calculated to evaluate the pass rate;

Ø 3.5-inch large color LCD display screen, clearer display content, and more convenient on-site viewing

Ø Laser positioning for more accurate on-site observation of steel reinforcement position

Six scanning modes, including thickness, waveform, profile, grid, specification, and image detection, are used to detect internal steel bars in concrete, adapting to components of different sizes, resulting in more intuitive results and wider applications;

Ø Dense steel bar waveform recognition, even the spacing between ultra small steel bars can be clearly determined, making it intuitive and accurate for determining the number of steel bars without leakage;

Four methods, including laser, sight, sound, and indicator light, are used to indicate the position of steel bars, the thickness of the protective layer, and the central axis of adjacent steel bars;

A more user-friendly grip design for the handle;

The LCD screen can adjust the brightness according to the current brightness, making it more suitable for various detection environments;

Adopting multiple combined measurement methods with multiple coils, the positioning calculation is more accurate and the accuracy is higher;

Manual correction of reinforcement function, which can manually correct reinforcement leakage due to operation during the detection process based on waveform, and automatically calculate spacing and protective layer thickness;

Equipped with automatic shutdown settings, the automatic shutdown time can be set according to one's own usage situation;

Accurately identify the position of steel bars and the middle position of adjacent steel bars, display the thickness of the protective layer and the spacing between steel bars at the same time, making drilling and coring more convenient;

During the detection process, one click reset makes calibration more convenient;

There are two methods of data transmission: wired transmission and wireless transmission;

Built in high capacity safe lithium battery with low power consumption design, it can operate for extended periods without charging;

Professional data analysis software, closely related to national norms and standards, with nine report formats available for automatic generation and printing of inspection reports;

4、 Technical parameters:


Applicable range of protective layer thickness(mm)

Ф6~Ф50
Maximum range (mm)First range:2~100    Second range:2~200
Maximum allowable error in protective layer thickness

2~80     ±1(mm)

80~120    ±2(mm)

120~160   ±3(mm)

160~200   ±4(mm)

Applicable range of diameter measurement(mm)Ф6~Ф50
Estimating the diameter of steel barshave
Thickness detectionhave
Waveform detectionhave
Grid detectionhave
Image Detectionhave
JGJ detectionhave
Profile detectionhave
Laser positioninghave
Scan rangeborderless
Data correction work (spacing/thickness)have
Data transmission mode wireless/USBhave
display screen640x480
Power supply modeBuilt-in Lithium Battery
Host size(mm)240x93x110
Weight(kg)0.67


Specification Parameters


保护层厚度适用范围(mm)Ф6~Ф50
最大量程(mm)第一量程:2~100    第二量程:2~200
保护层厚度最大允许误差2~80     ±1(mm)      
80~120   ±2(mm)
120~160  ±3(mm)      
160~200  ±4(mm)
直径测量适用范围(mm)Ф6~Ф50
估测钢筋直径
厚度检测
波形检测
网格检测
图像检测
JGJ 检测
剖面检测
激光定位
扫描范围无边界
数据修正功(间距/厚度)   
数据传输模式 无线/usb
显示屏640x480
供电方式内置锂电池
主机尺寸(mm)240x93x110
主机重量(kg) 0.67


File Download

Contact Us

Communicate with professionals to quickly obtain solutions

By Telephone

010-80330210 ★ 13810805582 ★ 13581938686【诚招代理】 (9:00-18:00)

WeChat QR Code Scanning